Products

Single Point Load Cell FIT®/4

Special features

  • 4 limit switches with hysteresis
  • Dosing functionalities and diag- nostic channel (Type E)
  • Fast triggering and scaling of the measured value
  • Trigger function (external or level trigger)
  • PC-Software for parameter ad- justment and dynamical analysis
  • Integrated overload protection
  • Test report for 3000 d accord. to OIML R 60, R 76

Type

FIT/4...

Accuracy class according to OIML R60

C3

Max. capacity (Emax)

Min. load cell verification interval (vmin)

Min. application range for 3000 d

kg

g kg

5

0.5

1.5

10

1

3

20

2

6

50

5

15

75

10

30

Max. platform size

mm

L 400 x W 400

L 600 x W 500

Max. number of load cell verification intervals (nLC) Apportionment factor (pLC)

3000

1

Temperature effect on sensitivity (TKC)1) 2)

in temperature range 0 5C...+40 5C [32 5F...+104 5F]

Temperature effect on zero signal (TKS0)2)

% of Cn/10K

±0.0250

±0.0200

Hysteresis factor (dhy)1) 2)

Nonlinearity (dlin)1) 2)

Creep (dCR) over 30 min

Eccentric loading error acc. to OIML R76

% of C

±0.0166

±0.0166

±0.0166

±0.0233

Service load (EU); max. 120 mm eccentricity Safe load limit (EL); max. 20 mm eccentricity Permissible dyn. load (Fsrel)

max. 50 mm eccentricity

% of Emax

150

1000

70

Deflection at max. capacity (snom)

mm

< 0.2

Power supply:

Supply voltage UB1 (DC) Power consumption Switch-on current

V W A

+ 10 ... +30

� 2

0.15

Resolution of meas. signal (1 Hz-Filter)

Measuring rate

Adjustable cut-off frequency of the digital filters: Filtermode 0

Filtermode 1 (response time 62 ... 365 ms) Baud rate (RS-232-, RS-485-interface)

Max. number of bus members

Bit

1/s

Hz Hz Baud

20

4 ... 1200

200 ... 0.25

18 ... 2.5

1200; 2400; 4800; 9600; 19200; 38400; 57600;

115200

90