Type |
AD103C | |
Accuracy class |
0.01 | |
Number of trade values, accord. to EN 45 501 (R76) |
e |
10 000 |
Input sensitivity |
µV/e |
0.5 |
Measuring range |
mV/V |
± 2.0 |
Input signal range, max. |
± 3.0 | |
Measuring signal resolution, max. |
bit |
24 |
Measuring rate (depending on output format and baud rate) |
Hz |
1200 ... 4.7 |
Cutt-off frequency of the digital filter (− 3 dB), adjust. |
200 ... 0.25 | |
Bridge excit. voltage UB (Excit. from supply voltage) |
VDC |
5 ±5 % (= supply voltage) |
Measuring signal input, SG transducer (Full bridge) |
Ω |
≥40...40001) |
Transducer connection |
|
6-wire circuit |
Input resistance (differentiell) |
MΩ |
>15 |
Transducer cable length |
m |
≤ 100, calibration incl. cable |
Interface cable length RS-232 |
m |
≤ 15 (25-pol. Sub-D-female connector) |
Calibration signal |
mV/V |
2 ± 0.01 % |
Temperature stability of the calibration signal |
ppm/°C |
≤ 2.5 |
Linearity deviation (related to full scale value) |
% |
±0.002 |
Temperature effect on zero point (related to full scale value) measuring sensitivity (related to actual value) |
%/10 K |
typ. ± 0.0025; max. 0.005 typ. ± 0.0025; max. 0.005 |
Interface |
|
RS-232 |
Baud rate, adjustable |
bit/s |
1200 ... 115 200 |
Diagnostics interface (RS-232) |
kbit/s |
ASCII/Binary |
Protocol | ||
Baud rate |
38.4 | |
Node address |
|
0...89 |
Length of interface cable, max. |
m |
≤ 15 |
Supply voltage |
VDC |
5 ±5 %; Residual ripple ≤10 mV (p.p.) |
Current consumption (wthout load cell) |
mA |
≤ 90 |
Nominal temperature range |
°C [°F] |
−10 ... +40 [14...104] |
Operating temperature range |
−20 ... +60 [−4...140] | |
Storage temperature range |
−25 ... +85 [−13...185] | |
Dimensions (LxWxH) |
mm |
93 x 53 x 17 |
Weight, approx. |
g |
40 |
Degree of protection to EN60529 (IEC 529) |
|
IP00 |
AD103C - datasheet | PDF, 0.2 Kb |